• adaptec maxview storage manager manual

    adaptec maxview storage manager manual

    Download Link: ➡ adaptec maxview storage manager manual



    File Name: adaptec maxview storage manager manual.pdf
    Size: 4635 KB
    Type: PDF, ePub, eBook
    Category: Book
    Uploaded: 9 May 2019, 14:52 PM
    Rating: 4.6/5 from 750 votes.


    Last checked: 1 Minutes ago!









    ⬆ LINK ⬆




















    In order to read or download adaptec maxview storage manager manual ebook, you need to create a FREE account.

    eBook includes PDF, ePub and Kindle version



    ✔ Register a free 1 month Trial Account.
    ✔ Download as many books as you like (Personal use)
    ✔ Cancel the membership at any time if not satisfied.
    ✔ Join Over 80000 Happy Readers


    Book Descriptions:

    adaptec maxview storage manager manual

    All 3 services are currently required to be able to run maxView.Yes, VMware CIMPAT and vSphere SNMP are supported. No, we have moved away from applets in our storage manager with maxView. Features such as task scheduler, email notification, OS event logging, etc.The web server is started on port 8443 by default and customers have the option to use other web servers on a different port. Microsemi is an industry-leading company and moving to maxView is no different. With this adoption, it allows us to be aligned with many of the virtualization programs (VMware, Xen) in the field today because many are no longer allowing proprietary protocols due to security concerns. Additionally, maxView supports many browsers and allows the user to access and control their systems with flexibility and efficiency. The architecture has been designed to obtain the configuration based on events to put minimal load on the adapter. In upcoming releases, we will be upgrading to new primefaces library and this will allow us to provide a richer user interface with an improved look and feel. When FreeBSD can run on CIM, we will be able to support FreeBSD for maxView. Find out more on how we use cookies and how you can change your settings by clicking here. Microsemi and the Microsemi logo are registered trademarks of Microsemi Corporation. All other trademarks and service marks are the property of their respective owners. For a better experience, please enable JavaScript in your browser before proceeding. It may not display this or other websites correctly. You should upgrade or use an alternative browser. It seems that the topic has received little attention in recent times. All I could find was this post, lastly updated 2013. Back in these times the software was called Adaptec Storage Manager. And there are no Wiki articles still living covering the topic. Every link referencing them is dead, respectively pointing to a nonexisting site.

    • adaptec maxview storage manager manual, adaptec maxview storage manager manual, adaptec maxview storage manager manual download, adaptec maxview storage manager manual pdf, adaptec maxview storage manager manual free, adaptec maxview storage manager manual software.

    Adaptec Command Line Interface Utility (ARCCONF). Adaptec maxCache Plus Command Line Interface Utility (MAXCONF)In the case of conflict between variousThe following information is available in this file:It is not backwardIn each case, acknowledge Any drive without Adaptec RAID It does not support storageOn Linux systems,Use ARCCONF to create Example: with anDoing so ensures that email Otherwise, However, to ARCCONF terminates the task.Otherwise, the support archive will Once the migration isDoing so may cause displayAlternative: add the GUI IP To refresh theApply and close. However, for logical drives Both the maxView Event ViewerOn the maxViewAs a result, if you hot remove a disk This issue is seen with SAS Creating a support archive For instance, the Enclosure statusAs a result, maxView alwaysAll Rights Reserved. This software is protected under international copyright laws and The information in this document is proprietary and confidential to. PMC-Sierra, Inc., and for its customers' internal use. In any event,Strongly Agree Agree Neutral Disagree Strongly Disagree Comments. To see a complete list of supported operating systems see the Product Specifications Ideal for bandwidth intensive storage applications; NAS, OLTP servers, web servers, and digital surveillance. Please install this card only into server or PC chassis with recommended airflow (200 LFM). To see a complete list of supported operating systems see the Product SpecificationsFedoraLinux Driver SourceMicrosoftSuSE LinuxUbuntuUnixVMware. The default port is recommended (5988). If you want to use a different There is no guarantee that any port number besides For more information The default port is recommended (8443). If the default port is For more information on the. It is not required to install software on the client side to run maxView, all that is needed is to install maxView services on the server side. Could the number of services be reduced.

    Just download, try to find the portion of that big file you really need and try. Again: I have no idea if the adaptec does that or not.I want to try out the LXC solution before installing any additional software on my PVE server. And an example might help me a lot. Just download, try to find the portion of that big file you really need and try.I think the main part of this file is the web frontend software (tomcat, JavaEE app, etc.). I'll give this a try as second. I think the main part of this file is the web frontend software (tomcat, JavaEE app, etc.). I'll give this a try as second.Therefore I downloaded the latest version for linux from the Microsemi website: and unpacked the archive. I declined this, to be able to access the webinterface from LAN. The software uses PAM for authentication so I was able to login with the local admin account. We think our community is one of the best thanks toTens of thousands of happy customers have a Proxmox subscription. Get your own in 60 seconds.By continuing to use this site, you are consenting to our use of cookies. Learn how to calculate your overhead burden using our free interactive tool and use it to determine the right price for your IT services. Start calculating Now! It shouldn’t make a difference, but I’ll check. Additional steps may be required to complete the installation, depending on your operating system. The default password is password. A valid user name and password are required to access a Linux system from a remote Storage Manager client. The user ID must have root privileges on the host system. A Issue: December 4, 2012. Unique storage innovations featured on certain RAID adapters include maxCache caching software, Zero-Maintenance Cache Protection (ZCMP) and maxCrypto controller-based encryption (CBE.) All adapters feature maxView storage manager, which provides an HTML5 web interface that can be used in standard desktops and mobile browsers for all storage configuration and management needs.

    According to this post the Storage Manager is installed on PVE itself, correct me if I'm wrong. Hopefully somebody has successfully installed the software and can provide me some hints to do the same. Thank you very much. Kind regards. ------ UPDATE: my recent post shows how I solved the problem. For other raid monitoring devices, often you can just install the CLI binary and run it without any problems, at least that is what we do with e.g. the MegaCLI, hpsacucli or the amcli tools. For other raid monitoring devices, often you can just install the CLI binary and run it without any problems, at least that is what we do with e.g. the MegaCLI, hpsacucli or the amcli tools.Why do you want to access it from the host and the guest. The idea is that you only have to access it from the guest if you only want to have some reporting capability. The container solution is only viable if you do not get it to work directly on PVE due to only rpm packages or library mismatches. At least for the tools I tried, you can just extract the rpm and run the cli tools manually. Yet I've never tried to get some web frontend running, which also comes with some tools. I just use the cli tools for the storage to get the status of disks behind hardware raid.But I am not aware of how to use it. According to some research this would be a special file that acts like an interface on the LXC between the RAID controller and the application that wants to make use of it. I guess this is not existing out of the box. If so, how can I create and mount such a device file? The idea is that you only have to access it from the guest if you only want to have some reporting capability. I just use the cli tools for the storage to get the status of disks behind hardware raid.I am using Icinga2 and it would be sufficient if I get the desired RAID monitoring information by command line tools. Kind regards. If so, how can I create and mount such a device file?Again: I have no idea if the adaptec does that or not.

    Upon being installed, the software adds a Windows Service which is designed to run continuously in the background. Manually stopping the service has been seen to cause the program to stop functing properly. It adds a background controller service that is set to automatically run. Delaying the start of this service is possible through the service manager. The primary executable is named StorServ.exe. The setup package generally installs about 15 files and is usually about 318.51 KB (326,156 bytes). The installed file driverUpdate.exe is the auto-update component of the program which is designed to check for software updates and notify and apply them when new versions are discovered. Relative to the overall usage of users who have this installed on their PCs, most are running Windows 7 (SP1) and Windows 10. While about 75% of users of maxView Storage Manager come from the United States, it is also popular in South Africa and Russia. StorServ.exe - Adaptec Storage Manager Service Thank you for commenting!' Help others learn more about this software, share your comments. Learn more Learn more Learn more Learn more Learn more Check to see. Learn more Learn more Learn more Learn more See your XenServer installation guide Learn more Learn more Learn more Learn more Learn more Learn more Open a Case Online. A valid service agreement may be required.? A valid service agreement may be required.?It will then walk through the process of partitioning and formatting your RAID drives. It will also walk through how to find the current firmware version on your device. Also it will recommend some general streaming tips when using the NI HDD-8266. This should ship with the 8266 driver. But if you need the driver for a different OS, or do not have the have access to the DVD you can download the driver software here. This will bring you to a page that looks like the figure below. Then download the file from the next web page, it it does not occur automatically.

    SmartRAID adapters also feature backwards compatibility, broad operating system support and CPU platform diversity. They have been added to our trusted Smart Storage platform to support deployments that use fewer drives and can benefit from cachingThe SmartRAID 3100 series also unlocks all the features and performance of the 12 Gbps HBA 1100 Series of host bus adapters when the drives are configured as raw devices. The SmartRAID family continues its battery-free portfolio. The SmartRAID 315x series integrates flash-based cache protection to enable instant cache protection. The tethered Adaptec ASCM-35F capacitor module supports a five-year lifetime and is continuouslySmartRAID 3162 adapters also feature integrated cache backup circuitry, NAND Flash memory and field-replaceable super capacitors.Find out how the SmartROC 3100 and SmartIOC 2100 handle these advanced security features using maxCrypto controlled-based encryption (CBE). The web interface is very convenient for business as it will also allow you to manage multiple servers with Adaptec controllers. Links present on this article have therefore been updated accordingly. Then, you will be able to ignore the security exception displayed by your favorite web browser. Thus, the servers will listen on the IP address 127.0.0.1. Allowing you to access the web interface only if you are on the same PC as the server. If you are the company's system administrator and you need to access the controller settings from another computer network (or even from the Internet if the router is properly configured for this use), you should uncheck this box. This shortcut will redirect you to the address: Ignore this warning and add an exception for this site (depending on your browser). Example: building a RAID volume. The most common release is 1.00.00.20206, with over 98% of all installations currently using this version.

    WORKAROUND: enable power management for the logicalAdaptec Series 7 controllers do not support ATAPI CD-ROM, DVD,WORKAROUND: upgrade to FW 1.5.FW SN11, a medium error might result in SCSI command timeouts. This condition might be seen whenThe LED blinks continuously if blinked from ARCCONF orSeries 7 controllers. WORKAROUND: upgrade to FW AD63D usingX9SCL-LN4F or X9DRi-F motherboards. The maximum number of drives in a RAID 50 or RAID 60 differWith a degraded RAID 10 logical drive, the drive is rebuiltThe Verify with Fix operation (in maxView Storage Manager and. ARCCONF) is NOT available when:Other tasks. The logical. The logicalARCCONF is backward compatible with older Adaptec controllerADDTOPOOL or REMOVEFROMPOOL.In the maxView Storage Manager online help, some linksAll Rights Reserved. This software is protected under international copyright laws andThe information in this document is proprietary and confidential to. In any event. Find out how you canMonitor and network monitoring in general. You are invited to get involved by asking andThere are no mib files. How I can moitor the RAID? Also, it depends on what type of system these cards are running on to see if it might be possible to monitor it through the OS. Linked below is a pdf with directions on how to set up SNMP for the Adaptec RAID Devices. It looks like you will need the Adaptec Storage Management software installed. What it looks like you may be able to do through is to have the MaxView software write to the OS event log which you can then have PRTG monitor. Also, you may be able to have the software write logs and use a file sensor to monitor that but it seems that they really want you to use their monitoring software with that controller. Can PRTG use this? Seems to be such as WMI. Unfortunately we don't have this software or that type of RAID controller in house so you would need to search for it once you have the software installed or ask their tech support. Use at your own risk.

    Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available. Please upgrade your browser or activate Google Chrome Frame to improve your experience. Press Esc to cancel. However, our tech gurus are adept with the many flavours on the Hypervisor rainbow and for various non-critical or non-production systems we do make use of other HV’s, including VMware ESXi nodes. One of the more annoying issues with ESXi up until the last 1-2 years, was the inability to monitor the status of your RAID card without rebooting and checking via the RAID BIOS — which is inconvenient to say the least in today’s highly available world. The ESXi version allowed you to “remotely” monitor the RAID controller status by communicating with the underlying hypervisor via the virtual machine layer ie.Of course from there, you could integrate into whatever automated monitoring system you use, ie. Nagios, for automated alerts of disk or RAID issues. More features, more problems! You will need to manually create a VMware ESXi installation.iso with the correct aacraid driver included for your RAID card. Here you will find the latest available aacraid drivers for your card to work with ESXi 5.1. Once you have the aacraid drivers, follow the steps below: Change to the above mentioned directory (example: cd c:\vm). Firstly the correct VMware Installation Bundles (VIB’s) installed for Adaptec RAID Controller monitoring via the Common Information Model (CIM) service running on ESXi. Secondly, you will need a virtual machine to install the monitoring software “maxView Storage Manager” for your Adaptec RAID Card. However, we just want to check everything is ok on the ESXi 5.1 host Select “Troubleshooting Options”, then select “Enable SSH”. Hit ESC twice. Click on Options and Start. Log in as root. If it’s not, you must have installed using magic.

    Please choose the version that matches your OS (the instructions will be for Windows). Make sure to leave all the ports as default unless you know you need a specific configuration.You will use your computer User Name and Password for your computer to log into the maxView client, unless you specified a different User Name and Password. But you can notice the different tabs on the left-hand side of the maxView Storage Manger interface and the options at the top of the screen, as well as an overview of your PC. Your disk now shows up as unallocated in the Disk Management utility with a black bar across the top. Choose a drive letter and click Next Follow the onscreen prompts to navigate the screen. Learn more about our privacy statement and cookie policy. Our team of experts can help. Our team of experts can help. In the case of conflict between variousThe following information is available in this file:BIOS, and command lineNOTE: The latest versions of firmware, BIOS, driver softwareThe drivers on this DVD have been tested and certified onCompatibilityWindows Drivers:Windows. Windows. Server 2012, 2008, 32-bit and 64-bit. Server 2008 R2, 64-bit. Storage Server 2008 R2 (all versions). SBS 2011 (all versions)Linux Drivers:Red Hat Enterprise Linux 6.2, 5.8, IA-32 and x64. SuSE Linux Enterprise Server 11, 10, IA-32 and x64. Debian Linux 6.0, IA-32 and x64. Ubuntu Linux 12.04, 11.04, 10.04, IA-32 and x64. Fedora Linux 16, 15, 14, IA-32 and x64. CentOS 6.2, 5.8. FreeBSD Drivers:VMware Drivers:Solaris Drivers:AdaptecAdaptec. SAS RAID Controllers Installation and User's Guide. RAID Controller Command Line Utility User's Guide. Storage Manager User's Guide. SAS RAID Controllers Quick Start Guide (multi-lingual). HTML and Text Format:The Adaptec SAS RAID Controllers Installation and User's GuideUser's Guide contains complete installation information for. ARCCONF. The maxView Storage Manager User's Guide containsManager software.

    Bootable DVD mode is not supported in this release--the abilityDynamic Kernel Module Support (DKMS) are provided in the. RAID Controllers Installation and User's Guide. DKMS ensuresBefore attempting to install an operating system in uEFI mode,The installation may failInstalling Solaris 11 Express on a bootable array is notTo avoid a known PCIe Active State Power Management issue underThe new lineSCSI Device Partition Name in Debian’s GRUB bootloader withIn the GRUB bootloaderTo avoid thisSCSI command timeout value from 30 seconds (the defaultFailure to increase the timeout mayUse these commands toSeries 7 controllers only. It is not backwards compatible withUse ARCCONFTo log in and use maxView Storage Manager on a Windows 8 system,MS Live account. To create a local user account:Provide account details. Start maxView Storage Manager and log in with your local userTo ensure that the maxView Storage Manager CIM Server initializesTo change maxView Storage Manager's login credentials after changingThe maxCache Container pre-fetches hot data blocks only forOnce the pre-fetch is complete, the container is consideredThe Installation DVD does not eject the DVD drive when youRegardless of which device you select to install the OS, theLinux will fail to boot if you delete or swap away Device 0. For example, if you create three arrays in the BIOS--VOL-0. VOL-1, and VOL-2--install the OS on VOL-1, then swap VOL-0Restore the originalIdeally, you shouldTo remove the hotStorage Manager and the BIOS differs. Example: with an. Adaptec 72405 and 7805 installed, the BIOS reportsHowever, to change theOtherwise, the support archive willOnce the migration isManager GUI until you refresh the display (by pressing F5).Storage Manager displays two 'Unassign Spare' icons on theOnly the one on the first row isBack to refresh the display.On Linux, maxView Storage Manager may fail to connect with. To avoid this problem, add theIt is always disabled.

    NOTE: Only the Guest OS versions of maxView Storage Manager can be used with VMware. The Guest OS must be installed on a VM that resides on the ESXi host that contains the controller(s) that are to be monitored. NOTE: The 32-bit Guest OS versions should not be used on 64-bit VMs. NOTE: At the time of this writing, Linux Guest OS support is for rpm-based Linux versions only. This example will assume a minimal Linux CentOS x64bit VM, 256MB RAM, thin provisioned. Here you will find the latest available “maxView Storage Manager” for VMware. As of writing latest was “ maxView Storage Manager v1.02.20532 for VMware “ Previous versions of ESXi arcconf used port 5989 which I have specified here without problem.For Windows locally, double-click on the maxView icon from the desktop. Stop the maxView Web Server, then stop the maxView Storage Manager Agent. Then start the Agent and then start the Web Server. An expert with a Samurai sword; Jada indulges himself with HBO documentaries, fitness fiend Tony Horton and authentic Japanese cuisine. Jada also holds the record for the fastest hard drive hot swap, unfortunately thats not Guinness certified much to his dismay. Subscribe to our monthly newsletter and get free tips from the experts! The plugin determines the status of Raidsets, RAID-Controllers and of individual discs (S.M.A.R.T), while all stripe sets are supported. Args: getconfig 1 al. Timeout: 15. Controllers found: 1Controller Model: Adaptec 6405E. Controller Serial Number: 12345678901. Physical Slot: 3. Installed memory: 128 MB. Copyback: Disabled. Background consistency check: Disabled. Automatic Failover: Enabled. Global task priority: High. Stayawake period: Disabled. Spinup limit internal drives: 0. Spinup limit external drives: 0. Defunct disk drive count: 0. NCQ status: Enabled. Statistics data collection mode: EnabledDriver: 7.1-0 (30034). Boot Flash: 5.2-0 (19109)Logical device name: RAID1. RAID level: 1. Status of logical device: Optimal. Size: 953334 MB.

    Read-cache setting: Enabled. Read-cache status: On. Write-cache setting: Enabled. Write-cache status: On. Partitioned: Yes. Protected by Hot-Spare: No. Bootable: Yes. Failed stripes: No. Power settings: DisabledSegment 1: Present Controller:1,Connector:0,Device:1) ABCDABState: Online. Supported: Yes. Reported Channel,Device(T:L): 0,0(0:0). Reported Location: Connector 0, Device 0. Vendor. Model: ST1000NM0011. Firmware: SN03. Serial number: ABCABC. Reserved Size: 538264 KB. Used Size: 953344 MB. Unused Size: 64 KB. Total Size: 953869 MB. Write Cache: Enabled (write-back). FRU: None. S.M.A.R.T.: No. S.M.A.R.T. warnings: 0. Power State: Full rpm. Supported Power States: Full rpm,Powered off. SSD: No. Device is a Hard drive. State: Online. Reported Channel,Device(T:L): 0,1(1:0). Reported Location: Connector 0, Device 1. Serial number: ABCDAB. Command completed successfully. Copyright (C) 2011 LuftEngineering GmbH. Monitors integrity of a RAID System with arcconf. Usage:NOT for use with nagios.


  • Commentaires

    Aucun commentaire pour le moment

    Suivre le flux RSS des commentaires


    Ajouter un commentaire

    Nom / Pseudo :

    E-mail (facultatif) :

    Site Web (facultatif) :

    Commentaire :